PC6000 SOFTWAREOperationsManualPC6000++--
Getting Started Section 2YSI Incorporated PC6000 Software Operations Manual 61. Connect one end of your YSI cable to the sonde and the other to the co
SECTION 3USING PC6000 TO CAPTURE, RETRIEVE ANDANALYZE DATACAPTURE – ALL SONDESOnce you have learned how to carry out Discrete Sampling studies using t
Capture, Retrieve and Analyze Data Section 3YSI Incorporated PC6000 Software Operations Manual 8The parameters listed in the lower part of the display
Capture, Retrieve and Analyze Data Section 3YSI Incorporated PC6000 Software Operations Manual 9Select number 1-Directory to view all files currently
Capture, Retrieve and Analyze Data Section 3YSI Incorporated PC6000 Software Operations Manual 10In the File menu, when you select 3-Quick Upload, the
Capture, Retrieve and Analyze Data Section 3YSI Incorporated PC6000 Software Operations Manual 11highlight the desired file and then press Enter to a
SECTION 4 PC6000 MENUS4.1 FILE MENUThe File menu option of PC6000 software allows you to specify and customize reports and plotsbased on data that has
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 13Filename: SAMPLE.DATMODIFY VIEW SYSTEMParameters... Header Print ReportCon
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 14Select Detail this parameter to view the detailed information of a highligh
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 15Example:12/31/92 23:59:59 1001/15/93 16:02:00 982/15/93 18:00:00 94In this
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 16The Control Info menu allows you to report or plot an entire file, or any p
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 17The increase (INC) and decrease (DEC) plots are types of sequential plots.
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 18Once you copy data into the manual scaling column, it can be modified. Aft
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 19Sensor Type Minimum Maximum Mean Std.Dev.Temperature (C) 4.69 21.00 5.88 2.
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 20Active definition: default report/plotSelect an action: Select a definition
4.2 SETUP MENUHighlight Setup from the PC6000 menu bar and press Enter to configure the PC program to yourspecifications.------DISPLAY-FORMATS---- ---
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 22Under DISPLAY-FORMATS change any default values that are not appropriate by
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 23The Data capture setup screen will appear similar to the one shown below.Pa
PC6000 Menus Section 4YSI Incorporated PC6000 Software Operations Manual 24a meaningful display of your data. These selections will become easier wit
SECTION 5 ADVANCED SETUPThese options are provided for the advanced user who has special requirements of PC6000. It isimportant to remember that the
iCONTENTSSECTION 1 INTRODUCTION 1SECTION 2 GETTING STARTED 22.1 Installing PC6000 Software 22.2 Running Software 32.3 Software Setup 32.4 Communicatin
Advanced Setup Section 5YSI Incorporated PC6000 Software Operations Manual 26A ten-digit integral number of seconds past midnight March 1, 1984.NUM (n
Advanced Setup Section 5YSI Incorporated PC6000 Software Operations Manual 27Select Export file format: PRN to setup a format if you wish to e
SECTION 6 TROUBLESHOOTINGThis section contains a troubleshooting table that will be helpful to identify the causes of themost common difficulties that
SECTION 7 CONTACT INFORMATIONFor any questions regarding PC6000 software, or any YSI equipment, please contact YSI TechnicalSupport at (800) 897-4151
SECTION 8 SENSOR DRIFT APPLICATION NOTESENSOR DRIFT COMPENSATIONThe following application note is designed to facilitate the use of the sensor drift s
Sensor Drift Compensation Section 8YSI Incorporated PC6000 Software Operations Manual 313- The user must now write compensation files which contain th
Sensor Drift Compensation Section 8YSI Incorporated PC6000 Software Operations Manual 32the cursor on the "DO (mg/L)" entry, press "Ret
SECTION 9 ACCESSORIESSTANDARD EQUIPMENT WITH YSI SONDES" 600R, 600XL, 600XLM, 6820, 6600 or 6920 Sonde with Calibration Cup" EcoWatch for Wi
Accessories Section 9YSI Incorporated PC6000 Software Operations Manual 34" 6077B CE Calibration Cable, 10 ft. (3m)" SP6093-L Special field
Accessories Section 9YSI Incorporated PC6000 Software Operations Manual 35DISPLAYS, LOGGERS, AND ACCESSORIES" 610-D Handheld Field Display with A
Accessories Section 9YSI Incorporated PC6000 Software Operations Manual 36
Item # 069305Drawing # A69305July 1998 1700/1725 Brannum LaneYellow Springs, Ohio 45387 USA(800) 765-4974 (937) 767-7241FAX: (937) 767-9320Websi
SECTION 1 INTRODUCTIONThe PC6000 program is very useful in the operation of the YSI Sondes, and is provided as an optionwith every sonde. This PC-bas
SECTION 2 GETTING STARTED2.1 INSTALLING PC6000 SOFTWAREPC6000 software can be used with an IBM-compatible PC with at least 256KB of RAM andDOS 3.0 or
Getting Started Section 2YSI Incorporated PC6000 Software Operations Manual 32.2 RUNNING SOFTWARETo start the software, make your current drive C:\PC6
Getting Started Section 2YSI Incorporated PC6000 Software Operations Manual 4Select the Baud option to check the baud rate. The baud rate should be 9
Getting Started Section 2YSI Incorporated PC6000 Software Operations Manual 5The PC6000 menu flow chart will help you visualize the relationship betwe
Comments to this Manuals